Revision Date: August 16, 2021
Interstitial Detector
(Liquid-Phase)
Click on the vendors specific EQUIPMENT NAME to go to that Listing.
VENDOR
|
EQUIPMENT NAME
|
OPERATING PRINCIPLE
|
Beaudreau
Electric, Inc.
|
Model DFR-1 Liquid Level Switch, Models
EOS100, 510 and 516 Discriminating Sensors with Models 500 and
500C Controllers, Model 522 Remote Monitoring System, Model 522T
Monitoring System, and ESite Monitoring System |
float switch
(Model DRF-1),
refractive index of liquids
(Model EOS100),
polymer strip, hydrocarbon-only
(Model 510),
optical sensor and conductivity
(Model 516) |
Beaudreau
Electric Marketing, LLC
|
Model MPC100 Liquid Controller with Models
DCS140L, DCS140NL Liquid Sensors and Model DCS140D
Discriminating Liquid Sensor |
float switch
|
Cambria Corporation |
Models EOS80, EOS100, and
EOS120 Discriminating Sensors with Beaudreau Electric, Inc.'s
Models 522 Remote Monitoring System and Model 522T Monitoring
System, and Cambria Mark I Monitoring System |
Evanescent wave absorption
/ refractive index of liquids |
Containment Solutions, Inc. (originally listed as Fluid
Containment which was formerly O/C Tanks)
|
DDAS
910 Discriminating Sensor for Dry Annular Spaces; DCBS 900
Discriminating Sensor for Collars, Bulkheads, Sumps
|
capacitance
change
|
|
FOVF
600B, FOVF 600S Non-Discriminating Sensors for High Level
Overfill (Brass, Steel); FCBS 700 Non-Discriminating Sensors for
Collars, Bulkheads, Sumps; FDAS 710 Non-Discriminating Sensor
for Dry Annular Spaces; FHRB 810 Non-Discriminationg Sensor for
Reservoirs
|
float
switch
|
EBW,
Inc.
|
AutoStik
Sensors LS-5, LS-7, LS-10, LS-15, LS-20, LS-35, LS-3A, LS-30A
|
float
switch
|
Franklin Fueling Systems |
Incon
TS-1001/2001, TS-5, TS-550, TS-5000, TS-550evo, TS-5000evo, EVO
600 and EVO 6000 Consoles with FMP-DIS Discriminating Interstitial
Sensor and FMP-EIS Electro-Optical Interstitial Sensor |
conductivity, electro-optic
|
|
Incon
TS-1001/2001, TS-5,TS-550, TS-5000, TS-550evo and TS-5000evo,
EVO 600 and EVO 6000 Consoles with FMP-DDS Discriminating
Dispenser Sump Sensor and FMP-DTS Discriminating Turbine Sump
Sensor |
float
switch |
|
Incon
TS-1001/2001, TS-5, TS-550, TS-5000, TS-550evo, and TS-5000evo,
EVO 600 and EVO 6000 Consoles with FMP-HFS Horizontal Float
Switch, FMP-HFS2 Horizontal Float Switch, FMP-HLS High Level Float
Switch, FMP-HIS Hydrostatic Interstitial Float Sensor, and
FMP-HIS-XL Hydrostatic Interstitial Float Sensor |
float
switch |
|
Tank
Sentinel TS-5xxx Series with TSP-DMS 12 and 24 Inch
Discriminating Magnetostrictive Sensors |
Magnetostrictive probe with dual floats |
|
S940
Alarm Console with TSP-HFS Horizontal Float Switch Sensor,
TSP-HLS High Level Sensor, TSP-UHS Universal Hydrostatic Sensor,
and TSP-ULS Universal Liquid Sensor |
float/reed switch |
|
Incon
TS-1001/2001, TS-5, TS-550, TS-5000, TS-550evo, TS-5000evo, EVO
400, EVO 200, S940 Alarm Console, EVO 600, and EVO 6000 Consoles
with FMP-ULS Universal Liquid Sensor, FMP-UHS Universal
Hydrostatic Sensor, FMP-ULS-C Universal Liquid Sensor Chemical,
FMP-ULS-PS Universal Liquid Sensor Position Sensitive sensors |
qualitative
continuous
float/reed switch |
|
Franklin Fueling Systems EVO 400, EVO 200, EVO 600, and EVO 6000
Consoles with FMP-DDS-U Discriminating Dispenser Sump Sensor and
FMP-DTS-U Discriminating Turbine Sump Sensor |
qualitative
continuous
float switch |
|
Franklin Fueling Systems EVO 400, EVO 200, EVO 600 and EVO 6000
Consoles with FMP-DIS-U Discriminating Interstitial Sensor and
FMP-EIS-U Electro-Optical Interstitial Sensor |
qualitative
continuous
conductivity, electro-optic |
|
Franklin
Fueling Systems EVO 400, EVO 200, EVO 600 and EVO 6000 Consoles
with FMP-HIS-U Hydrostatic Interstitial Float Sensor, and
FMP-HIS-XL-U Hydrostatic Interstitial Float Sensor |
qualitative
continuous
float switch |
|
EVO 600 and EVO 6000 Consoles with TSP-DIS BriteSensor and TSP-EIS Standard Sensor |
electro-optic |
|
EVO 600 and EVO 6000 Consoles with TSP-DMS 12 and 24 Inch Discriminating Magnetostrictive Sensors |
Magnetostrictive probe with dual floats |
|
EVO 600 and EVO 6000 Consoles with TSP-HFS Horizontal Float, TSP-HLS Standard Sensor, TSP-ULS, and TSP-UHS Standard Sensors Switch |
float/reed switch |
|
EVO 600 and EVO 6000 Consoles with TSP-HIS BriteSensor and TSP-HIS-XL Sensor |
float/reed switch |
Franklin Fueling Systems
(originally listed as INCON Intelligent Controls, Inc.) |
Tank
Sentinel TS-1000EFI, TS-1001/TS-2001, and TS-5xxx Series with
TSP-DIS BriteSensor;
Tank Sentinel TS-1000/TS-2000, TS-1001/TS-2001, and TS-5xxx
Series with TSP-EIS Standard Sensor;
Tank Sentinel TS-1000/TS-2000 with TSP-PS Liquid Contact Sensor |
opto-electric |
|
Tank
Sentinel TS-1000EFI , TS-1001/TS-2001, and TS-5xxx Series with
TSP-HIS BriteSensor;
Tank Sentinel TS-1000/TS-2000, TS-1001/TS-2001, and TS-5xxx
Series with TSP-HLS Standard Sensor, TSP-ULS, and TSP-UHS Standard Sensors |
magnetic
switch
|
Franklin Fueling Systems (originally listed as
Beaudreau Electric, Inc.) |
Model 404-4
Controller with Models S404 and S406
Liquid Level Sensors |
float switch
(Model S404),
refractive index of liquids (Model S406) |
Fuel Oil Systems
|
Gems LS-750, Innovative
Solutions L176-0108-0803 (Kele FS7SS), and Madison M4602-XXXX
Sensors with Fuels Oil Systems Console - FOS-0160-1, software
version 001 |
float
switch
|
Gems Sensors, Inc. (originally listed as Warrick
Controls, Inc.
|
DMS-47X-X-X(-X),
DMS-57X-X-X(-X) Monitoring Panels with
Models DLP-1-NC, DLP-2-NC, DLP-2-NO Sensors |
float
switch
|
|
Model
DFP-25 Sensor |
product
solubility
|
Integrated Control Systems |
SD1-SP and SD1-DP Safety Disconnect Liquid Sensors |
float/reed switch
|
Morrison Bros. Co. |
924LS, 924 and 925 Sensor for use with the 918AC, 918S, 918D and 918Q Alarm Console |
float
switch |
Oklahoma Environmental Services (originally listed as Arizona
Instrument Corp., then NESCO, and then Summit Holdings, Inc. - Oklahoma Environmental, Inc.) |
Soil Sentry Liquid 330(17-330-A/17-330-B), TLM-830, ENCOMPASS
APAM with
Probes 17-141A, 17-142A, 17-143A, 17-144A
|
refraction
|
OMNTEC
Mfg., Inc.
|
Controller
Models OEL 8000 11, K-OEL 8000 11 with Liquid level Sensors
BX-L, BX-LS, BX-LWF, BX-RES |
optical
sensor |
|
Controller
Models OEL 8000 11, K-OEL 8000 11 with Liquid level Sensors
BX-PDS, BX-PDWF, BX-PDWS |
optical
sensor, conductivity |
|
Controller Models Series LPD, LU, OEL8000 with Sensors L-LL-R-1,
LS-ASC, PDS-ASC, PDWS-1, PDWF-1 |
refractive
index of liquids (all), electrical
conductivity (PDS-ASC, PDWS-1, PDWF -1)
|
|
Controller Models OEL 8000 III (Proteus B, K, and X Consoles) with Liquid level Sensors BX-PDS, BX-PDWF, BX-PDWS, BX-LS, BX-LV, BX-LWF, BX-RES |
optical sensor (all), electrical conductivity (PD-PDS, BX-PDWF, and BX-PDWS) |
OPW Fuel Management
Systems
(originally listed as Emco Electronics, Tuthill Transfer
Systems) |
EECO
System, Leak Sensor II, Leak Sensor Jr.
Thermistor and Proximity probes
|
thermal
conductivity, proximity switch
|
|
EECO
2000, 3000, Leak Sensor II, Leak Sensor Jr. Systems Q0001-005
Interstitial Space Flood Sensor, and
EECO 1500, 2000, 3000 Systems
Q0003-005 Wet Interstitial Sensor
|
float
switch
|
|
EECO
1500, 2000, 3000 Systems
Q0003-001 Discriminating Dispenser Pan Sensor,
Q0003-002 Discriminating STP Sump Sensor,
Q0003-003 Discriminating Interstitial Sensor,
Q0003-006 Liquid Only Interstitial Sensor,
Q0003-009 Liquid Float Sensor
|
float
switch and polymer strip
(Q0003-001, Q0003-002),
optical prism and conductivity (Q0003-003),
optical prism (Q0003-006),
float switch (Q0003-009) |
OPW Fuel Management
Systems |
iSite, iTouch, and EECO Series Fuel Management Systems with OPW
Intelligent Sensor (and Company Equivalent): 30-231-S, 30-0230-S
(30-3221-1A/1B, Q003-009); 30-0231-L (30-3221-1);
30-0232-D-10/D-20/D-10B/D-20B (Q0003-001/002); and the 924B Sump
Sensor |
float switch |
OPW Fuel Management
Systems
(originally listed as Petro Vend, Inc.) |
Petrosentry
IV, Petrosentry VIII, SiteSentinel with Liquid Sensor, Universal
Sump Sensor, Universal Reservoir Sensor |
thermal
conductivity (Liquid Sensor)
float
switch (Universal Sump Sensor, Universal Reservoir Sensor)
|
PermAlert
|
PAL-AT Models AT20C, AT50C,
AT40K with
PHL
Hydrocarbon Sensor
|
electrical
conductivity
|
|
TankWatch
Models PHM10, PHMS,
Combination Hydrocarbon/Water Probe, Hydrocarbon Probe
|
electrical
conductivity
|
|
PAL-AT Models
AT20C, AT30C, AT50C, AT75C, AT20K, AT30K, AT40K, AT80K with PHLR-S/L and PHLR-P-S/L
Hydrocarbon Probes |
Product permeable, magnetic membrane switch |
|
LiquidWatch Leak
Detection System LW64-IS with PHLR-LW and PHLR-P-LW
Hydrocarbon Probes |
Product permeable, magnetic membrane switch |
PMP Corporation
|
PMP Piping Sump Sensor 63228 and 63229 |
float
switch
|
|
PMP Tank Interstitial Sensors 63409, 63420, and 63460 as evaluated with the Veeder-Root TLS-350 (software version 11.02) |
float
switch |
|
PMP
Tank Interstitial Sensors 63510 and 63520 as evaluated with the
Incon TS-2001 Tank Sentinel, Part #: T2P/8
|
float
switch |
|
PMP
Piping Sump Sensor 63228 and 63229 as evaluated with the
Veeder-Root TLS-350 (firmware version 336)
|
float
switch |
|
PMP
Tank Interstitial Sensors 63409, 63420, and 63460 as evaluated
with the Veeder-Root TLS-350 (firmware version 336)
|
float
switch |
Pneumercator
Company, Inc.
|
LC
1000 Series, E-14-29, E-700-1, LDE-700, LDE-740, TMS 2000, TMS
3000 with Level Sensor Models LS600AB, RSU800
|
float
switch
|
|
LC
1000 Series, LC 2000 Series, E-14-29, E-700-1, LDE-700, LDE-740, TMS 2000,TMS 2000W, TMS
3000 with Level Sensor Models LS600 Series, LS600LD Series, LS610
|
float
switch
|
|
LC
1000 Series, LC 2000 Series, E-14-29, E-700-1, LDE-700, LDE-740, TMS 1000 Series, TMS
2000, TMS 2000W, TMS 3000 with Level Sensor Models RSU800, RSU810
|
float
switch
|
|
LDE
700, LDE 740, LDE 9000
Sensor Probe Models 9-901, 9-902, 9-903
|
capacitance
|
|
TMS 2000, TMS
3000 with ES820-100 Non-Discriminating Liquid Sensor, ES820-200 Discriminating
Liquid Sensor |
optical
sensor
|
|
LC2000, TMS 2000,
TMS 3000 with ES825-100F, 100XF, 100CF Non-Discriminating Liquid Sensor,
ES825-200F, 200FX Discriminating Liquid Sensor |
optical sensor, electrical
conductivity |
|
TMS 1000, TMS 2000W (wireless) with ES825-300F, 300XF, 300CF
Non-Discriminating Liquid Sensor, ES825-400F, 400XF
Discriminating Liquid Sensor |
optical sensor, electrical
conductivity |
|
Tamper-Resistant, Non Discriminating LS600LDxx-T and Discriminating LS600LDxx-FT/FLT Liquid Float Switch Leak Sensors with Console Model: LC1000-Series, LC2000-Series, TMS1000-Series, TMS2000-Series, TMS3000-Series, and TMS2000W-Series,MS 1000 |
|
Preferred
Utilities Manufacturing Corporation
|
TG-EL-D3
Controller with HD-A1 Sensor
|
optical
sensor, electrical conductivity
|
|
PWCN-4-CDXRxxx
Controller, RBS Non-Discriminating Sensors for Sumps and
Containements; PS-LDS Non-Discriminating Sensor for Sumps and
Containments; PLS Non-Discriminating Sensor for Reservoirs |
reed switch/float |
|
TG-EL-D4A Fuel Sentry Control
Unit, HD-A2-C Optical Discriminating Sensor |
optical sensor |
Robertshaw Industrial
Products |
Centeron High Level Alarm
System (SM Series Switch Monitor with Centeron FSL Series Float
Switches: Models *FSL AAA BB CC DD EE 0 and *FSL AAA BB CC DD EE
C) |
reed switch |
Ronan
Engineering Co.
|
Ronan
Controller Models X76S; X76VS; X76LVC; TRS76; X76ETM, LVCS;
X76CTM-N4; X76ETM-4X; X76-4X, -3, -6, -9, -12; X76AST-4X with
Ronan Sensors LS-3 N.C.; LS-3 N.O.; LS-30; LS-7; HVA; LS-3SS;
LS-1
|
float
switch
|
S Bravo Systems, Inc. |
Model B-2000 Shallow
Steel Dispenser Containment System, Model B-8600
Aboveground/Marina Steel Dispenser Containment System |
float switch |
Simmons Corp (originally
listed as
Caldwell Systems Corp.)
|
Simmons/Caldwell Tank
Manger Liquid Sensor, Version TMLIQ
|
ultrasonic
|
Simone
Engineering, Inc.
|
Magnetrol
Model 918 Ultrasonic Point Level Switch with ABB Automation
Freelance 2000 Control System
|
electrical
conductivity, ultrasonic
|
Tidel
Engineering, Inc.
|
EMS-3500
Liquid Discriminatory Probes Part 301-0635,
Containment
Sump Probes Part 301-0642,
Tidel Detector #301-0752-001
|
electrical
conductivity/hydrocarbon sensitive polymer
(Part 301-0635)
magnetic
switch/float and hydrocarbon sensitive polymer (Part 301-0642)
float
switch
(#301-0752-001)
|
Tyco Thermal
Controls LLC (originally listed as Raychem Corp.) |
TraceTek
Alarm and Locator Modules
TT502,
TT5000, TT3000 Fuel Sensing Cable
|
electrical
conductivity |
Tyco Thermal
Controls LLC |
TraceTek Alarm and
Locator Modules
with TT-FFS Fast Fuel Sensor |
electrical
conductivity |
Universal
Sensors and Devices, Inc.
|
Leak
Alert System
Models LAL-100, LA-01, LA-02, LA-04, LA-X4, LA-08, DLS-01,
LS-20, LS-36, LS-70, CATLAS
Liquid Sensor LALS-1
|
thermal
conductivity |
Veeder-Root (originally
listed as Gilbarco Environmental Products and later as Marconi
Commerce Systems)
|
PA02590XXX000 (Same as Veeder-Root 0794390-401, 404, 407, 409),
PA02591144000 (Same as Veeder-Root 0794390-420, 460),
PA02592000010 (Same as Veeder-Root 0794380-206)
|
float
switch |
Veeder-Root
(originally listed as Marley Pump Co.) |
Red
Jacket Electronics RE400-179-5 to RE400-199-5 Combination High
Level/Low Level Sensor, RE400-042-5 Hydrostatic Sensor,
Red Jacket PPM 4000 with Optical Liquid Discrimination
Sensor |
float
switch (RE400-179-5 to RE400-199-5, RE400-042-5)
optical sensor (PPM4000) |
|
Red Jacket
Electronics RE400-058-5, RE400-059-5, RE400-147-5, RE400-148-5
Overfill Sensor, RE400 111-5 Sump Sensor, RE400-203-5 Optical
Liquid Discrimination Sensor, RE400-204-5 Dispenser Pan Monitor,
RE400-180-5 Liquid Refraction Sensor |
float
switch (RE400-058-5, RE400-059-5, RE400-147-5, RE400-148-5,
RE400-111-5), electrical conductivity and optical (RE400-203-5),
conductive polymer (RE400-204-5),
optical
(RE400-180-5)
|
Veeder-Root
|
ILS-250,
350, TLS-250i, 250i Plus, 300, 300C, 300i, 300PC, TLS-350 Series,
TLS-450 Series, Red Jacket ProMax and ProPlus with Interstitial
Liquid Sensor for Fiberglass Tanks 794390-401, 404, 407, 409,
Interstitial Liquid Sensor for Steel Tanks 794390-420, 460, Liquid
Sensor for Sumps 794390-206 |
float
switch
|
|
TLS-350 Series, TLS-450
Series, Red Jacket ProMax with Interstitial Liquid Sensor
794380-341, Dispenser Pan Sensor 794380-320, Discriminating
Containment Sump Sensor 794380-350, Discriminating Fibretrench
Sensor 794380-360, 361, 362 |
capacitance
change/ultrasonic (794380-341)
electrical
conductivity/ultrasonic (794380-320, 350, 360, 361, 362)
|
|
TLS-300, 300i, TLS-350
Series, TLS-450 Series, Red Jacket ProMax and ProPlus with Discriminating
Dispenser Pan Sensor 794380-322, Discriminating Containment Sump Sensor
794380-352 |
product
permeable, reed switch/float
|
|
Dispenser
Pan Sensor (847990-001) and Differentiating Dispenser Pan Sensor
(847990-002) With Dispenser Control Interface |
product
permeable, reed switch/float
|
|
TLS-300 Series, TLS-350 Series, TLS-450 Series,
EMC Series, EMC Basic, Red Jacket ProMax and ProPlus with Single
Stage Hydrostatic Sensor 794380-301, Dual Stage Hydrostatic
Sensors 794380-302, 303 |
float
switch
|
|
ILS-350, TLS-300C, 300i,
300PC, 350, 350PC, 350R, 350RPC, TLS-450 Series, Red Jacket
ProMax and ProPlus with Solid-State Pan/Sump Sensor 794380-321,
351, Piping Sump Sensor 794380-208, 209, Micro Sensor 794380-340 |
float/reed
switch (794380-208, 209), optical (794380-321, 340, 351) |
|
TLS-350, 350R Series,
TLS-450 Series, Red Jacket ProMax with Discriminating Interstitial Sensor
794380-343, Micro Sensor 794380-344 |
optical sensor
and conductivity
(794380-343)
optical sensor
(794380-344) |
|
ILS-350, TLS-300 Series, TLS 350
Series, TLS-450 Series, EMC Series, EMC Basic, Red Jacket ProMax and ProPlus
with Position Sensitive Sensor 794380-323 |
float switch |
|
TLS-350
Series, TLS-450 Series, EMC, EMC-PC, EMC Enhanced, EMC-PC
Enhanced, and Red Jacket ProMax with Magnetostrictive Sump Sensor
Series 857060-xxx* and 857080-xxx* |
magnetostrictive probe with dual
floats |
|
ILS-350, TLS-300 Series,
TLS-450 Series, EMC, EMC-Series, and Red Jacket ProMax, Red Jacket
ProPlus with Single-Point Mini Hydrostatic Sensor 794380-304 |
float switch |
|
TLS-300 Series, TLS-350 Series, TLS-450 Series, EMC Series, EMC
Basic, Red Jacket ProMax and ProPlus with Float Sensor 794380-430 |
float switch |
|
TLS-350, 350R Series,
TLS-450 Series, Red Jacket ProMax with Interstitial Sensor
794380-345
|
optical sensor |
|
TLS-4; TLS-4B; TLS-300,
300C, 300i, 300PC; TLS-350, 350PC, 350R, 350R-PC; TLS-450 Series; Red Jacket ProMax and ProPlus,
and ProPlusPC with Position Sensitive Interstitial Sensor
794380-333 |
Float/reed switch |
|
8601 Series, 8600 Series, and TLS-3xx Series with Interstitial Liquid Sensor for Fiberglass Tanks 794390-409 |
float
switch |
|
8601 Series with Sump Sensor 794380-208, Sump Sensor 794380-209 |
Float/reed switch |
|
8601 Series with Single-Point Hydrostatic Sensor 794380-301, Dual-Point Hydrostatic Sensor 794380-303, Single-Point Mini Hydrostatic Sensor 794380-304 |
Float/reed switch |
|
8601 Series with Position Sensitive Pan/Sump Sensor 794380-323, Position Sensitive Interstitial Sensor for Steel Tanks- 333 |
Float/reed switch |
|
8601 Series with Interstitial Sensor for Steel Tanks with 4’ to 12’ I.D. with 16’ cable 794390-420, Interstitial Sensor for Steel Tanks 794380-430, Interstitial Sensor for Steel Tanks with 4’ to 12’ I.D. with 30’ cable 794390-460 |
float switch |
|
8601 Series with Mag Sump Sensor 857060-XXX, Mag Sump Sensor 857080-XXX |
magnetostrictive probe with dual
floats |
|
8601 Series with Solid-State Discriminating Dispenser Pan Sensor 794380-320, Discriminating Dispenser Pan Sensor 794380-322 |
product permeable, float/reed switch |
|
8601 Series with Solid-State Discriminating Interstitial Sensor for Fiberglass Tanks (4’ to 10’ I.D.) 794380-343, Solid-State Interstitial Sensor for Double-wall Fiberglass Tanks 794380-345 |
optical sensor and conductivity (794380-343), optical (794380-345) |
|
8601 Series with Solid-State Discriminating Containment Sump Sensor 794380-350, Discriminating Containment Sump Sensor 794380-352 |
product permeable, solid-state (-350)
product permeable, float/reed switch (-352) |
|
8601 Series with Solid-State Dispenser Pan Sensor 794380-321, MicroSensor 794380-344, Solid-State Containment Sump Sensor 794380-351 |
optical sensor |
|
|